Construction Consulting Laboratory, International (CCLI)


Testing Services Includes:

  • Air Infiltration
  • Static and Dynamic Water Penetration
  • Structural
  • Thermal
  • Seismic
  • Missile Impact Testing
  • Power Platform Staging Inspection, Testing, and Certification
  • Impact Resistance in Accordance with Testing Protocols PA201, PA202, PA203

Proud Member of the

American Architectural

Manufacturers Association

 

Distinguished 20 Year Member

We offer these specific tests:

  • AAMA 501 “Methods of Test for Exterior Walls”

  • AAMA 501.1 “Standard Test Method for Exterior Windows, Curtain Walls and Doors for Water Penetration Using Dynamic Pressure”

  • AAMA 501.2 "Field Check of Metal Storefronts, Curtain Walls, and Sloped Glazing Systems for Water Leakage"

  • AAMA 501.3 "Field Check of Water and Air leakage through Installed Exterior Windows, Curtain Walls, and Doors by Uniform Air Pressure Difference"

  • AAMA 501.4 “Recommended Static Test Method For Evaluating Curtain Wall and Storefront Systems Subjected To Seismic and Wind Induced Inter-story Drifts”

  • AAMA 501.5 “Test Method for Thermal Cycling of Exterior Walls”

  • AAMA 502 "Specification for Field Testing of Windows and Sliding Glass Doors"

  • AAMA 503 "Specification for Field Testing of Meal Store Fronts, Curtain Walls and Sloped Glazing Systems"

  • AAMA/NWWDA 101/IS.2 “Voluntary Specification for Aluminum, Vinyl (PVC) and Wood Windows and Glass Doors”

  • ASTM E72 “Strength Tests of Panels for Building Constructions/Materials”

  • ASTM E 283 “Standard Test Method for Determining Rate of Air Leakage through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen”

  • ASTM E330 “Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference”

  • ASTM E 331 “Standard Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference”

  • ASTM E 488 “Strength of Post Installed/Cast-in-Place Anchors in Concrete / Masonry Elements”

  • ASTM E 575 “Recommended Practice for Reporting Data from Structural Tests of Building Constructions, Elements, Connections, and Assemblies”

  • ASTM E 547 “Standard Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Cyclic Static Air Pressure Differential”

  • ASTM E 754 “Pull-out Resistance of Ties/Anchors Embedded in Masonry/Mortar Joints”

  • ASTM E783 "Standard Test Method for Field Measurements of Air Leakage Through Installed Exterior Windows and Doors"

  • ASTM E11O5 "Standard Test Method for Field Determination of Water Penetration of Installed Exterior Windows, Curtain Walls, and Doors by Uniform or Cyclic Static Air Pressure Difference"

  • Texas Department of Insurance “Building Code for Windstorm Resistant Construction”

  • Miami-Dade County Impact Resistance in Accordance with Testing Protocols PA201, PA202, PA203


Construction Consulting Laboratory, International
(972) 242-0556 Fax: (972) 245-6047